Qatar Yellow Pages Online
changsha friend xperimental analysis instrument Co.Ltd.

changsha friend xperimental analysis instrument Co.Ltd. - | E-Showroom

Home » Products »  FDR-4671 Free Glycerin and Total Glycerin in Biodiesel tester

FDR-4671 Free Glycerin and Total Glycerin in Biodiesel tester

Add Review
Price : On Request



Scope

    Biodiesel free and total glycerin has a thermal conductivity detector, hydrogen flame ionization, electron capture, flame photometric, five kinds of nitrogen and phosphorus detector can be equipped with a packed column or a capillary column. The instrument can be programmed temperature thermostat operation, or third-order operation. Instrument is highly integrated, advanced design, to achieve a higher degree of automation, it can detect parameters, temperature parameters set by the keyboard implementation. Can packed column and capillary pressure and stigma real-time display, the instrument uses a single air route structure, reasonable structure, stable and reliable performance, simple operation, easy maintenance.

Features

1, with power self-diagnosis function, stopwatch function (to facilitate flow measurement), running timer, power storage protection, keyboard lock and power supply with anti-interference function mutation.

2, automatic fault diagnosis: analysis end automatic exceeded prompted, provide diagnostic meet the national standard three ratios, TD shown, the component concentrations shown a variety of fault diagnostics and so on.

3, oven volume, intelligent opened the door and out of the system infinitely variable air volume, reducing the program up / cool down time after the system is stable equilibrium; furnace system :( temperature range) Ambient temperature + 6 ℃ ~ 400 ℃ .13-order program heating, heating rate of 0-50 ℃ / min; Increment 0.1 ℃ / min can recalibrate the oven temperature by the user, and arbitrarily set maximum temperature. Furnace temperature equilibrium time determined by the user.

4, all computerized key operations, large-screen LCD display, man-machine dialogue, easy to operate;

 

Technical parameter

1. Temperature control

Temperature control range: room temperature 7℃ -400℃(incremental 0.1 degrees C)

Rise order: three order

Rise rate: 0.1 ℃ -50 ℃ /min (incremental 0.1 ℃)

2. Detector FID

Detection limit: less than 5 * 10-12g/s (sixteen -)

Baseline noise: less than 6 * 10-12A/H

The linear range is greater than or equal to 105

Stable time: less than 20min

3. Detector TCD

Sensitivity: 10000mV = ml/mg (sixteen -)

Baseline noise: less than 30uV (99.999 hydrogen carrier gas

4. FPD detector

Detection limit: ≤5 × 10-12g / s (N)

Baseline noise: ≤2 × 10-13A / H

  • Product Details
  • Brand :
  • Place of Origin : hunan,China
  • FOB Price : On Request
  • Minimum Order Quantity : 1
  • Supply Ability :
  • Packaging & Delivery
  • Packaging Detail : standard wooden case
  • Delivery Detail : 25 workdays